standards-testing

Salt Spray Testing (ASTM B117): Chamber Setup, Concentration, and Fog Dispersion

Engineering Overview: Engineering guide on ASTM B117 and ISO 9227 Neutral Salt Spray (NSS) chamber calibration, temperature control, and corrosion inspection criteria.

Technical & Engineering Specifications

Chamber Temp 35°C (95°F) Continuous Fog
Duration Tiers 96h (Grade 3), 240h (Grade 4), 480h+ (Grade 5)
Standard Reference ASTM B117 / ISO 9227 / EN 1670
Chamber Concentration 5% NaCl Salt Fog Solution

Accelerated Corrosion Chamber Protocol

ASTM B117 is the international standard for testing corrosion resistance across plated and PVD-finished lock cylinders.

Chamber Parameters

  • Salt Solution: 5% +/- 1% sodium chloride (NaCl) in deionized water (pH 6.5–7.2).
  • Chamber Temperature: Continuous 35°C +/- 2°C.
  • Fog Dispersion: 1.0 to 2.0 mL/hr per 80 cm2 collector.
  • Inspection: Evaluated for pitting, blistering, and operational torque post-exposure.

Frequently Asked Engineering & Selection Questions

Q1: What conditions are used during ASTM B117 salt spray testing?

A 5% salt solution fog is continuously sprayed at 35°C inside an enclosed chamber for 96 to 480+ hours to test anti-corrosion finishes.