standards-testing

Axial Pulling Rig Testing: 15 kN Hydraulic Load Frame Metrology

Engineering Overview: Technical breakdown of laboratory tensile extraction testing, subjecting lock plugs to 15 kN axial pulling forces on calibrated tensile test rigs.

Technical & Engineering Specifications

Load Rate 10 mm/min Controlled Crosshead Speed
Test Standard EN 1303:2015 Clause 4.9.2 (Resistance to Pulling)
Acceptance Criteria Zero core separation; lock remains deadlocked
Applied Tensile Load 15 kN (1,500 kg force) Axial Pull

Laboratory Tensile Extraction Testing

To achieve EN 1303 Attack Grade D / SKG*, cylinders are mounted in high-tensile steel fixtures on a 100 kN universal hydraulic tensile testing machine.

Testing Sequence

  • Screw Insertion: A hardened M6 high-tensile extraction screw is torqued into the keyway.
  • Linear Pulling: A continuous axial tensile load is applied at 10 mm/min until reaching 15 kN (1.5 tons force), verifying that the core does not extract.

Frequently Asked Engineering & Selection Questions

Q1: How is a 15 kN plug pulling test conducted?

A hardened extraction screw is anchored into the keyway and pulled by a hydraulic machine with 15 kN of force to ensure the plug does not pull out.